| FEATURES: • Convenient 3/4" anchoring holes allow easy access for bolting enclosure to floor • The M6 rails are infinitely adjustable front to rear via slots and sliding nuts. A 7/16" socket is required to loosen the bolt and make adjustment. • Maximum rail spacing, front to rear, is 36"; three pair of rails are included • These rails can accept multi-vendor "server specific" side mounting adapters. • Reversible rails are marked with U count. The number "0" is at the center of the rail, running 22 up and 22 down the rail. • Cinch strap/wire tie locations on side of rails both horizontal and vertical. • Frames accepts standard Enhanced Series top and bottom panels • The front and rear doors and top panel have mesh panel inserts for ventilation. • Same door options as the Enhanced Series Enclosures. • Generous cable access • Cables can enter the enclosure through3 locations: • 24"W x 3.75"D opening in the bottom rear • 13.5"W x 4"D opening next to the rear opening • The standard center opening of 11.75"W x 14.75"D • Cable loop lance located at the bottom rear opening allow you to secure your incoming cable. • The side of the rear corner posts have three 2.5" x 6" knockouts • Top back of the enclosure has two 2.5" x 6" knockouts • Networking of cabinet frames is accomplished by bolting them together through holes in the side faces of the corner posts with common 1/4-20 hardware. • Split side panels, lighter for easier handling • Increased strength with center side posts between side panels |
Close this window to return
![]()

| • CME-42ES: optional front & rear vertical
cable management run in each rear corner post • HCM-W29ES: optional horizontal cable management spanning left to right in the top front/rear with "waterfall" edges to protect cables. • Up to four standard GLCC vertical power strips can be mounted to the two rear corner posts; two per post with optional bracket, part number PSB-ES2 • Up to 24 standard 1U x 19" EIA PDU's can be mounted in the spaces between the EIA rails and side panels; 12 per side. (Optional PDU brackets are required) • Because of the 0U PDU mounting, none of the 44U mounting space is lost. • HCM-D42ES: optional cable management is available for each row of three PDUs and can handle the 28 power cords to these PDUs • A fourth cable management run can be installed on each side for any cable that needs to be run from front to rear. • A total of eight horizontal cable management runs can be installed front to rear. • Each of these runs feed directly and uninterrupted into the rear vertical cable management • The rear cable management runs are aligned with the pass through holes in the frame and allow for easy cabinet-to-cabinet cable runs as well as from below or above. |
| • AT1:Retractable anti-tip legs mount to
the outside bottom of the frame and can be used when the cabinet is on glides or casters. • Retractability allows you to safely clear the aisle. • If the cabinet is directly on the floor it should be anchored. The anti-tip legs extend 10" out beyond the front of the frame, this is the amount of extension required due to the travel and weight of some servers. • Mounting of the anti-tip legs is from the inside of the cabinet through the bottom; a total of eight 1/4-20 bolts are supplied. |